Select your language

  • Lietuvių
  • Русский
  • English
  • HOME
  • PRODUCTS
      • Back
      • MECHATRONICS
      • DATA LOGGERS
      • MEASUREMENT DEVICES
      • QUALITY CONTROL SYSTEMS
      • DISPLAYS AND INDICATORS
      • PLC AND I/O SYSTEMS
      • SENSORS
      • MONITORING SYSTEMS
      • INFRARED CAMERAS
  • SERVICES
      • Back
      • Consulting
      • System design
      • System installation
      • Project management
      • Service and maintenance
      • Energy saving
      • Production process optimization
  • SOLUTIONS
      • Back
      • Fire Protection
      • Energy power
      • Oil and gas industry
      • Equipment and machinery production
      • Ship building and repairing
      • Beverage and food industry
      • Research and development
      • Data acquisition, Data logger
      • Test, trial, automation
      • Vibration measurement
      • Monitoring, Process control
  • NEWS
  • CONTACTS
      • Back
      • PARTNERS
  • MECHATRONICS
    • Electric actuators
      • Electrak 1
      • Electrak MD
      • Max Jac
      • Electrak XD
      • Electrak HD
      • Electrak LL
      • Electrak GX
      • Electrak LA14
      • Electrak LA24
      • Electrak Throttle
    • Linear drives
    • Servo drives
    • Screws
    • Linear guides
    • Stepper motors
    • Safety systems
    • Couplings
  • DATA LOGGERS
    • Data Logger Loggito
    • Data logger Expert Logger
    • Data Logger Expert Key
    • Data Logger LogMessage
    • Data Logger ProfiMessage
    • Data Logger for Mobile Measurement
    • Mobile energy-measurement case
    • Software
      • ProfiSignal
      • ProfiSignal 20
  • MEASUREMENT DEVICES
    • Mobile devices
      • Leak detector LD 500
      • Portable Thermometers
      • Dew point meter DP 500
      • TEST -4
      • Sensor tester ST 7PNG
    • Wireless devices
      • Wireless Transmitters
      • Wireless Receivers
    • Meters
      • Energy meters
  • QUALITY CONTROL SYSTEMS
    • Vision sensor CS 60
    • Profile sensor PS-30
  • DISPLAYS AND INDICATORS
  • PLC AND I/O SYSTEMS
  • SENSORS
    • Humidity Sensors
    • Current Transducers
    • Laser distance sensors
    • Optical sensors
      • Diffuse Sensors
      • Fork light barriers
      • Angled light barriers
      • Frame light barriers
      • Fiber-optic sensors
      • Light curtains
      • Contrast sensors
      • Color sensors
    • Position Sensors
      • Draw wire sensors
      • Linear variable differential transformers
    • Pressure Sensors
    • Label sensors
    • Flow Sensors
      • VA 500
      • Compressed air/ gases
    • Temperature Sensors
      • Thermocouples
    • Vibration Sensors
    • Load cells
  • MONITORING SYSTEMS
    • Temperature and humidity monitoring system
    • Vibration monitoring system
    • Manufacturing process monitoring system
  • INFRARED CAMERAS
    • Infrared camera Xi 80
    • Infrared camera Xi 400
    • Infrared camera Xi 410
    • Infrared camera PI 400i /PI 450i
    • Infrared camera PI 640i
    • Infrared camera PI 1M
    • Infrared camera PI 05M
    • Infrared camera PI 08M

Heat meters

Heat meters are designed to measure the consumption of heat energy being supplied to a system or taken from it with heat power from 100 W to 100 MW where heat medium is water.

Silumos-skaitikliai2

Heat meter consists of:

  • calculator,
  • flow transducer with pulse transmitter,
  • temperature sensors of type Pt 500. 

Heat meters in this configuration can be used in the same time to measure the consumption of cooling energy in rooms with air conditioning.

We have a range of heat meters to suit various needs and demands:

  • Wall Mounted,
  • Mounted Compact,
  • Ultrasonic Meters.
skaitiklis3

 

There is a possibility to connect heat meters in a network. Possibility to connect additional meters as:

  • water meter,
  • gas meter,
  • electric energy meter,
  • provided that they have a pulse output.

Heat meter can be read by different interfaces as:

  • RS 232,
  • RS 485,
  • M-Bus,
  • Lon Works.

Overview:

  • MID Approved,
  • BMS output,
  • Pulsed output [Kw/hr], M-bus or 4-20mA versions,
  • Dn 15-300 applications,
  • Battery [6 year life] or 230v AC versions,
  • IP54 protection rating,
  • EMC Class C according to EN1434,
  • Measurement range 5-150°C,
  • Ambient temperature: 0 - 55°C,
  • Temperature resolution: 0.01°C,
  • Measuring frequency 20 - 120 seconds,
  • Selectable annual billing date,
  • No data loss when battery removed,
  • PT500 sensors,
  • Optional version with two pulsed inputs available.

 

Have a question?

{rsform 2}

 

Inobalt
Vilhelmo Berbomo 10-242
Klaipeda LT-92221

info@inobalt.lt
+370 612 22499
Elektrinės pavaros
  • Aktuatoriai
  • Sliekinės sraigtinės pavaros
  • Precizinės pavaros
Jutikliai
  • Optiniai jutikliai
  • Induktyviniai jutikliai
  • Talpuminiai jutikliai
  • Lazeriniai atstumo jutikliai
  • Ultragarsiniai jutikliai
Mechatronika
  • Automatika
  • Saugos įranga
Monitoringo sistemos
  • Temperatūros ir drėgmės monitoringas
  • Vibracijų monitoringas
  • LEAN ir OEE monitoringas
  • Radio matavimo sistemos
  • Skaitikliai
© 2025 All rights reserved. Designed & Developed by Inobalt.